M. Hanif & Sons

Edwards E2M80 vacuum pump buying & maintenance guide for Pakistan

The Edwards E2M80 two-stage oil-sealed rotary vane vacuum pump delivers 74 m³/h effective pumping speed (80 m³/h displacement) at 50 Hz and reaches 1 × 10⁻³ mbar ultimate pressure. Check these five plant engineering points before buying or installing an E2M80 in Pakistan.

1. Always verify the 50 Hz curves (not 60 Hz US specs)

Pakistan's national electrical grid runs at 50 Hz (380V–415V three-phase). Overseas datasheets often highlight 60 Hz capacity (96 m³/h displacement / 3 kW). On 50 Hz power, size your chamber evacuation time using 80 m³/h displacement, 74 m³/h pumping speed, and a 2.2 kW 3-phase motor. Simulate your exact vessel volume with our Vacuum Pump-Down Simulator.

2. Check ultimate pressure with gas ballast open vs. closed

Always design process drying tolerances around the gas-ballast-open rating if your chamber releases moisture.

3. Protect pump oil against heavy water or solvent vapour loads

The E2M80's published maximum water vapour pumping rate is 0.3 kg/h. Wetter pharmaceutical vacuum tray dryers or solvent distillation columns should place an inlet cold trap or condenser upstream of the ISO40 intake port so liquid water never emulsifies inside the pump oil sump.

4. Use Ultragrade 19 oil & EMF oil mist filtration

Oil level sits between 4.0 L minimum and 6.3 L maximum, visible at the front sight glass. Using clean Edwards Ultragrade 19 (low back-streaming mineral vacuum oil) maintains ultimate vacuum pressure and protects rotary vanes from scoring. In pharmaceutical cleanrooms and indoor packaging halls, fit an EMF oil mist eliminator on the NW25 exhaust port to capture oil aerosol.

5. Rely on built-in anti-suckback valve protection

During industrial load-shedding or motor trips, the spring-loaded anti-suckback mechanism isolates the ISO40 inlet when operating with gas ballast closed, preventing oil and air from rushing backwards into your product vessel.

Products in this guide

Vacuum pumps
Edwards E2M80 two-stage rotary vane industrial vacuum pump supplied in Pakistan with forced-air cooling and 50 Hz three-phase motor

Edwards E2M80 Two-Stage Rotary Vane High Vacuum Pump

Oil-sealed two-stage Edwards high vacuum pump (80 m³/h at 50 Hz) engineered for pharmaceutical vacuum drying, chemical distillation, and oil degassing in Pakistan.

Displacement at 50 Hz
80 m³/h
Ultimate pressure
1 × 10⁻³ mbar
Motor at 50 Hz
2.2 kW (50 Hz)
PDF

Need a drive or pump sized for your plant?

Send us the duty — motor power, speed and mounting — and we will reply with suitable options and a price.

Request a quote
WhatsApp Engineer